SensLine System of Perimeter Sensors

SensLine System of Perimeter Sensors

SensLine System of Perimeter Sensors is a modern alternative to the traditional perimeter protection based on a sensor cable. The system is designed to protect any type of fencing against unauthorized access and destruction

SensLine System has been developed by a team of experienced engineers basing on their R&D works. The solution consists of a special, fence-mounted cable with modules (2 cm x 4 cm) spaced at a distance of 5 meters. The modules detect any movement in three planes. The central unit controls
the system and analyses signals separately for each module, enabling the system to configure individual parameters for each sensor. This solution enables the use of a single cable, even for fencing with various segment types. The modular structure of sensors ensures that any system damage or devastation affects only a 2.5-meter section of protected perimeter, and fault location is accurately diagnosed by the system.

Costs of SensLine System at the level of a traditional sensor cable

up to 75% cheaper

compared to systems with similar functionality available on the market

SensLine System of Perimeter Sensors is based on the technology, which provides high precision and functionality at significantly lower cost of implementation and maintenance, when compared to competitive systems available on the market that offer similar functionality

Innovations implemented in SensLine System of Perimeter Sensors enable the user to connect additional peripherals in desired location within the system, e.g.: PIR motion sensors, opening sensors, control of door locks or lighting control, and more. The functionality of the system enables the user to extend it at a low cost and with little effort. In practice, it provides the option for extending the system with e.g. automatic LED lighting for the violation point in the protected zone.

The system is extremely effective due to high precision of intrusion detection and specially designed algorithms that eliminate the impact of weather conditions. In addition, broad functionality and compatibility with the alarm systems of other manufacturers makes SensLine System of Perimeter Sensors extremely competitive in terms of price, when compared to solutions with similar functionalities.

Advantages of the SensLine System of Perimeter Sensors include: lower cost of implementation, precise location of intrusions, fast and economic of maintenance, flexible configuration of protected zones and significantly lower vulnerability to weather conditions and failures comparing to traditional sensor cables. All these features make the SensLine System optimal for perimeter protection of facilities.

Algorithms that eliminate

INFLUENCE OF ATMOSPHERIC CONDITIONS

SensLine System of Perimeter Sensors is provided with algorithms that reduce false alarms caused by weather conditions. This ensures better detection of intrusions during harsh weather than in case of conventional sensor cable.

Practice shows that at wind speeds exceeding 40 km/h, traditional sensor cables drastically increase the number of false alarms, which makes them virtually ineffective. Intelligent signal analysis eliminates a large number of false alarms caused by weather conditions, making SensLine System more precise and reliable.

40%

REDUCED FALSE ALARMS TRIGGERED BY WEATHER CONDITIONS


Low costs of repair and maintenance

OF SENSLINE SYSTEM

Effects of damaging or devastang SensLine System are limited only to a secon of 5m of the system. For comparison, a similar situaon with the use of a tradional sensor cable results in inacvaon of dozens or even hundreds of meters of perimeter protecon. 

SensLine System of Perimeter Sensors provides also fast and accurate diagnosis. Maintenance personnel receive the exact locaons of a failure.
Repair of the system is fast with dedicated repair sets. In the case of tradional soluons, the user must locate the problem by analysing the enre length of the installed sensor cable.

The system connuously monitors the status of individual modules and informs the user on any operaonal irregularies. System tests may take place at intervals of 60 seconds, according to the fourth protecon grade A, for systems of high risk level.

30%

LOWER COST OF REPAIRING DAMAGED SECTIONS


leg1place of system damage/devastationleg1no protection in a traditional sensor cable leg1no protection in SensLine system

Precise Alarm Location

BY SENSLINE SYSTEM

SensLine System ensures a high precision in indicating intrusion location. When an intruder crosses or damages the fence, security personnel receive the location data of this intrusion with an accuracy reaching 5 m. This precise information enables a quick response in the alarm location. For comparison, a traditional sensor cable provides the intrusion location with an accuracy of a few dozen to several hundred meters. 

5m

MAXIMUM ACCURACY OF INDICATING ZONE VIOLATION PLACE


Traditional sensor cable 

SensLine System of Perimeter Sensors

Technical Specifications

OF SENSLINE SYSTEM

Spacing of sensors on the sensor cable:

from 5.0 m

Precision of single intruder location:

compatible with the spacing of sensors/from 5.0 m

Number of alarm zones:

max. 200 (segment)

Operation of alarm zones:

independent

Alarm triggering criteria

excitation amplitude, excitation duration

Information on each sensor provided via bus:

yes

Simultaneous detection of several intruders:

yes

Detection of damage to the alarm zone

yes

Connection continuity test:

yes

Sabotage protection:

yes

Power consumption:

from 6 W to 10 W

Operating temperature range:

from -40 °C to +70 °C

Permissible relative humidity of the environment:

from 5% to 95%

Power supply voltage:

DC from +8,2 V to +36,0 V

Communication interfaces

RS-485, modules of IO, NC, NO typ

Number of output modules:

up to 60

Configuration of zones and sensitivity of sensors:

locally or remotely via the GSM SensLine module

Logic inputs

via SensLine Input / SensLine Adapter module

Entering the permitted zones (e.g. gates):

via SensLine Adapter module

SensLine Adapter may be used to assign a separate unprotected circuit, e.g. entrance gate. SensLine cable may be also installed on a gate, forming a ‘loop’, or burried under the entrance gate.

  • Precise location of violations – location of intrusion within the protected circuit is provided with an accuracy of up to 5 meters
  • Extensive analytics – specialized algorithms eliminate false alarms caused by weather conditions
  • Peripheral elements – option of connecting additional elements e.g.: PIR motion sensors, opening sensors, control of door locks or lighting control and others
  • Customised configuration – the number, size and sensitivity of protected zones may be configured according to specific features of the protected facility and its fencing
  • Compatibility – option of connecting all Alarm Units and operation with RS-485, GSM, IO, NC and NO modules
  • Precise diagnostics – the management module monitors the status of individual sensors and indicates their malfunction or damage
  • Quick servicing – precise location of the failure and quick repair with dedicated repair sets

ZONES FROM 5 M | HIGH SENSITIVITY | QUICK REPAIR | COMPATIBLE AND INTEGRAL SYSTEM | MOUNTED IN GROUND AND ON FENCE | UV RESISTANT |  LIMITED IMPACT OF WEATHER CONDITIONS

SensLine GSM provides the option of remote configuration of the system and adequate sensitivity of each sensor. The system may be also configured using a PC connected via USB.

Technical parameters

OF SENSLINE BRIDGE

Wthe guidelines take into account the Sensline Standard sensor cable, 3Hz band and the sensitivity of 700mg. Gravitational acceleration of 9,81 m/s^2.

SensLine Brigde – Logical part
Power supply voltage:   8 V – 13 V
Average current:    51 mA
Maximum current:   100 mA

SensLine Brigde – Sensory part
Power supply voltage:       12 V – 38 V
Maximum current:     3 A

Sensor cable SensLine
Current consumption:         0,105 [A/km]

Maximum allowable distance

SENSLINE BRIDGE

Maximum distance [m] for two separate lines

Power supply 12 V

800 m each line; a total of 1600 m.

Power supply 24 V

1000 m each line; a total of 2000 m

Power supply 36 V

not required

Power supply 12 V

800 m each line; a total of 1600 m.

Power supply 24 V

2000 m each line; a total of 4000 m

Power supply 36 V

2600 m each line; a total of 5200 m

Maximum distance [m] in a loop

Power supply 12 V

1200 m loop length

Power supply 24 V

1600 m loop length

Power supply 36 V

not required

Power supply 12 V

1200 m loop length

Power supply 24 V

3000 m loop length

Power supply 36 V

3600 m loop length

Formula for calculating battery capacity

SENSLINE SYSTEM

Advantages of

SENSLINE SYSTEM OF PERIMETER SENSORS

EXACT LOCATION OF VIOLATIONS

The location of intrusion within the protected circuit is provided with an accuracy of up to 5 meters

EXTENDED ANALYTICS

Specialized algorithms eliminate false alarms caused by weather conditions

PERIPHERAL ELEMENTS

Option of connecting additional elements e.g.: PIR motion sensors, opening sensors, control of door locks or lighting control and others.

CUSTOMIZED CONFIGURATION

The number, size and sensitivity of protected zones may be configured
according to specific features of the protected facility and its fencing

COMPATIBILITY

Option of connecting all Alarm Units and cooperation with RS-485, GSM, IO, NC, NO modules

PRECISE DIAGNOSTICS

The control module supervises the status of individual sensors and indicates their malfunction or damage

FAST SERVICING

Precise location of the failure and quick repair with dedicated repair sets

INSTALLATION FLEXIBILITY

Option of installing the Central Unit in a distance of dozens
or even hundreds of meters from the protected circuit

Need more informations?
Contact us!